Measuring principle |
Electromagnetic induction |
Electromagnetic induction |
Excitation frequency |
- DN 2 ... 65 (1/12“ … 2½”): 12.5 Hz
- DN 80, 100 (3”, 4”): 6.25 Hz
|
- DN 15 ... 50 (½“ … 2”): 12.5 Hz
- DN 80, 100 (3”, 4”): 6.25 Hz
|
Process connection |
|
|
Nominal size |
|
|
|
DN 2 … DN 100 (1/12" … 4") |
DN 15 … DN 100 (½” … 4") |
|
DN 10 … DN 100 (3/8" … 4") |
|
Mating flanges |
EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent
Option: DN 2 ... 10 (1/12” ... 3/8”): G½” / NPT ½” pipe connection adapters |
EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 or equivalent |
Rated operating conditions |
|
|
Ambient conditions |
|
|
Ambient temperature1) |
|
|
|
-40 … +100 °C (-40 … +212 °F) |
-40 … +100 °C (-40 … +212°F) |
|
-20 … +60 °C (-4 … +140 °F) |
|
- Compact transmitter MAG 5000/6000
|
-20 … +50 °C (-4 … +122°F) |
|
- Compact transmitter MAG 6000 I
|
-20 … +60 °C (-4 … +140 °F) |
|
- Compact transmitter MAG 6000 I Ex d
|
-10 … +60 °C (+14 … +140 °F) |
|
Temperature of medium |
|
|
|
-20 … +150 °C (-4 … +302°F) |
-20 … +200 °C (-4 … +392°F) |
|
-20 … +150 °C (-4 … +302°F) |
-20 … +180C (-4 … +356°F) |
|
-30 … +130 °C (-20 … +266F) Suitable for steam sterilization at 150 °C (302°F) |
|
Temperature shock |
|
|
|
|
|
- Duration ≤ 1 min, followed by 10 min rest
|
- DN 2, 3 (1/12”, 1/8”) No limitations
- DN 6, 10, 15, 25:
Max. DT ≤ 80 °C/min (¼”, 3/8”, ½”, 1”: Max. DT ≤ 80 K/min)
- DN 40, 50, 65:
Max. DT ≤ 70 °C/min (1½”, 2”, 2½”: Max. DT ≤ 70 K/min)
- DN 80, 100: Max. DT ≤ 60 °C/min (3”, 4”: Max. DT ≤ 60 K/min)
|
- DN 15, 25: Max. DT ≤ 80 °C/min (½”, 1”: Max. DT ≤ 80 K/min)
- DN 40, 50: Max. DT ≤ 70 °C/min (1½”, 2”: Max. DT ≤ 70 K/min)
- DN 80, 100: Max. DT ≤ 60 °C/min (3”, 4”: Max. DT ≤ 60 K/min)
|
|
Max. ±100 °C (210 °F) momentarily |
|
Operating pressure |
|
|
|
- DN 2 ... 65: 40 bar
(1/12” … 2½”: 580 psi)
- DN 80: 37.5 bar (3”: 540 psi)
- DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6abs1.5 x 10-5 psiabs bar |
- DN 15 ... 50: 40 bar
(½” … 2”: 580 psi)
- DN 80: 37.5 bar (3”: 540 psi)
- DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6abs1.5 x 10-5 psiabs) bar |
|
20 bar (290 psi)
Vacuum: 0.02 barabs (0.3 psiabs)
DN 80 ... DN 100: CO2 pressure max. 7 bar (101.5 psi) |
|
Mechanical load |
- 18 … 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 grms
- Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 grms
- Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 grms
- For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.
|
- 18 … 1 000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36
- Sensor: 3.17 grms
|
Enclosure rating |
|
|
|
IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min |
IP67 to EN 60529 (NEMA 4X/6), 1 mH2O for 30 min |
- Option on sensor (no ATEX)
|
IP68 to EN 60529 (NEMA 6P), 10 mH2O cont. |
IP68 to EN 60529 (NEMA 6P), 10 mH2O cont. |
EMC |
89/336 EEC |
89/336 EEC |
Design |
|
|
Weight |
See Dimensional drawings |
See Dimensional drawings |
Material |
|
|
|
|
|
|
Stainless steel AISI 316L (1.4404) |
Stainless steel AISI 316L (1.4404) |
|
|
|
|
Fibre glass reinforced polyamide (no ATEX) |
Stainless steel AISI 316 (1.4436) |
|
Stainless steel AISI 316 (1.4436) |
|
|
Stainless steel AISI 304 (1.4301),
Number and size to EN 1092-1:2001 |
Stainless steel AISI 304 (1.4301),
Number and size to EN 1092-1:2001 |
|
|
|
|
EPDM (max. 150 °C, PN 40 (max. 300 °F, 600 psi) |
Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi) |
|
- Graphite (max. 200 °C, PN 40 (max. 390 °F, 600 psi)
- PTFE (max. 130 °C, PN 25 (max. 270 °F, 300 psi)
|
|
- Pipe connection adapters:
DN 2, 3, 6 and 10 (1/12“, 1/8“, ¼” and 3/8”) |
- Stainless steel, AISI 316
- Hastelloy
- PVDF
|
|
Liner |
|
|
|
- DN 2, 3 (1/12“, 1/8“): Zirconium oxide (ZrO2)
- DN 6 ... 100 (¼" ... 4"): Aluminium oxide Al2O3
|
DN 15 ... 100 (½“, 4“): Aluminium oxide Al2O3 |
|
Reinforced PFA (no ATEX) |
|
Electrodes |
|
|
|
- DN 10 ... 100 (3/8" ... 4") : Platinum with gold / Titanium brazing alloy
- DN 2 ... 6 (1/12" ... ¼"): Platinium
|
Platinum with gold / Titanium brazing alloy |
|
- DN 10 ... 15 (3/8" ... ½") : Hastelloy C276
- DN 25 ... 100 (1" ... 4") : Hastelloy C22
|
|
Cable entries |
- Remote installation 2 x M20 or 2 x ½” NPT
- Compact installation
- MAG 5000/MAG 6000: 4 x M20 or 4x½”NPT
- MAG 6000I: 2 x M25 (for supply/output)
- MAG 6000I Ex d: 2 x M20 (for supply/output)
|
Remote installation 2 x M20 or 2 x ½“ NPT |
Certificates and approvals |
|
|
Conforms to |
PED – 97/23 EC and CRN (PFA) |
PED – 97/23 EC and CRN (PFA) |
Ex approvals |
|
|
MAG 1100 (Ceramic) |
|
|
- ATEX sensor or Compact with MAG 6000 I Ex
|
ATEX 2G D sensor Ex d e ia IIB T3 - T6 |
ATEX 2G D sensor Ex d e ia IIB T3 - T6 |
- Sensor with/without MAG 5000/6000 /6000 I
|
CSA/FM Class 1 div 2 |
CSA/FM Class 1 div 2 |
MAG 1100 (PFA) |
|
|
- Sensor with/without MAG 5000/6000/6000 I
|
CSA/FM Class 1 div 2 |
|