| Nominal size | DN 25 ... 40 (1” ... 1½”) | DN 50 ... 300 (2” ... 12”) | DN 350 ... 1200 (14” ... 48”) | 
| Measuring principle | Electromagnetic induction | 
| Excitation frequency | 12.5 Hz | 
DN 50 ... 65 (2” ... 2½“): 12.5 Hz 
DN  80 ... 150 (3” ... 6“): 6.25 Hz 
DN  200 ... 300 (8” ... 12“): 3.125 Hz | 1.56 Hz | 
| Process connection | 
| Flanges |  | Flat face flanges |  | 
|  | PN 40 (580 psi) | 
DN  50 ... 300: PN 16(2“ ... 12“: 230 psi)
DN  200 ... 300: PN 10(8“ ... 12“: 145 psi)
 | 
PN 10 (145 psi) 
PN 16 (230 psi) | 
|  | Class 150 lb | Class 150 lb ~20 bar (290 psi) | -- | 
|  | -- | -- | 28” ... 48”: Class D | 
|  | PN 16 (230 psi) DN 50 ... 1200 (2” ... 48”), 14 bar (232 psi) | 
| Rated Operation conditions | 
| Ambient temperature |  |  |  | 
|  | -40 ... +100 °C (-40 ... +212 °F) | 
| 
With compact transmitter MAG 5000/6000 | -20 ... +50 °C (-4 ... +122 °F) | 
| 
With compact transmitter MAG 6000 I | -20 ... +60 °C (-4 ... +140 °F) | 
| Operating pressure (Abs) | 0.01 ... 40 bar (0.15 ... 580 psi) | 0.03 ... 20 bar (0.44 ... 290 psi) | 0.01 ... 16 bar (0.15 ... 232 psi) | 
| Enclosure rating |  |  |  | 
|  | IP67 to EN 60529 / NEMA 4X/6 (1 mH2O for 30 minutes) | 
|  | IP68 to EN 60529 / NEMA 6P (10 mH2O continuously) | 
| Pressure drop at 3 m/s (10 ft/s) | As straight pipe | Max. 25 mbar (0.36 psi) | As straight pipe | 
| Medium conditions  |  |  |  | 
| Temperature of medium |  | 
|  | -10 ... +70 °C (14 ... +158 °F) | 
|  | -10 ... +70 °C (14 ... +158 °F) | 
| EMC | 89/336 EEC | 
| Design |  |  |  | 
| Weight | See dimensional drawings | 
| Material |  |  |  | 
|  | Carbon steel, St 37.2 | 
|  | Standard Fibre glass reinforced polyamide | 
|  | AISI 304 (1.4301) | 
|  | NBR Hard Rubber ((hydro carbon resistent)EPDM
 | 
|  | Hastelloy C276 | 
| 
Grounding electrodes standard | Hastelloy C276 | 
| Certificates and approvals | 
| Custody Transfer (only together with MAG 5000/6000 CT), order as special | OIML R 49 pattern approval cold water (Denmark and Germany): DN 50 ... 300 (2" ... 12") MI 001 cold water (EU): DN 50 ... 300 (2" ... 12") | 
| Approvals | CSA/FM Class 1, Div 2 | 
| Drinking water approvals |  | 
|  | NSF61 (Cold water, US)WRAS (WRc, BS6920 cold water, GB)
 ACS listed (F),
 DVGW W270 (D)
 Belaque (B)
 | 
|  | NSF61 (Cold water, US) | 
| Approvals | PED – 97/23 EC1) , CRN |